Visit the Below Website to access unlimited exam questions for all IT vendors and Get Oracle Certifications for FREE
http://www.free-online-exams.com
http://www.free-online-exams.com
Problem: PCP Setup is not working properly, unable to start the concurrent manager on N2
Configured the PCP setup after cloning but the Concurrent manager is not starting on node 2 when node 1 was down.
Symptoms:
Failover issue, if Node 1 is down Node2 is not coming up.
Managers are running on both nodes, ICM is on node 1.
FNDIMON is running on both nodes before that node 1 is down? {FNDIMON is running on only 2nd Node.}
Solution:
FNDIMON should run on both nodes.
So it should run on Node 1 before you put it down.
Go to System Administrator / Concurrent / manager / define
and query the fndimon for node 1.
Click on Work shifts button and check that you have declared 1 process. If not please do it .
Save and go to Concurrent / manager / Administer
Check that FNDIMON is ok on both nodes.
Retest the issue after you are sure the FNDIMON is running on both nodes (Actual= Target =1)
So it should run on Node 1 before you put it down.
Go to System Administrator / Concurrent / manager / define
and query the fndimon for node 1.
Click on Work shifts button and check that you have declared 1 process. If not please do it .
Save and go to Concurrent / manager / Administer
Check that FNDIMON is ok on both nodes.
Retest the issue after you are sure the FNDIMON is running on both nodes (Actual= Target =1)
How do you put the node 1 down ?
Using adstpall.sh
this is why you are not getting a failover!
Adstpall.sh will not give you a failover.
To get a failover you should bring down your node . Failover will happen when it is not possible to ping the node 1 .
adstpall only shutdown services normaly and we can still ping the node .
Summary : if Node1 is still available and pingable , there will not be a failover.
Using adstpall.sh
this is why you are not getting a failover!
Adstpall.sh will not give you a failover.
To get a failover you should bring down your node . Failover will happen when it is not possible to ping the node 1 .
adstpall only shutdown services normaly and we can still ping the node .
Summary : if Node1 is still available and pingable , there will not be a failover.
References:
Note 743716.1 How to Setup and Test Failover of PCP on Non-RAC Environments.
5 comments:
generic xanax xanax mixed with alcohol - xanax withdrawal is hell
buy tramadol online buy tramadol online reviews - tramadol overdose hallucinations
tramadol no rx buy tramadol 50mg online - tramadol dosage 15 pound dog
buy tramadol online what are tramadol 50mg tablets - buy tramadol online eu
cheap carisoprodol drug test soma carisoprodol - drug side effects carisoprodol
Post a Comment